Application
Isopad FIDBR-SR base drum heaters are used to provide medium flow and process temperature in hazardous environments. The special design including a self-regulating heating cable embedded in a solid metal housing ensures the maximum in safety at operating conditions. Using this design an additional temperature limiter is not necessary.
These heaters are designed for standard 200 liter drum sizes and are fully component approved according to the latest standards of ATEX.
Base drum heater
The base drum heater is a perfect addition to the the drum heater to prevent heat loss from below. A solid aluminium plate carries the heating cable and evenly distributes the temperature to the drum. An electromechanical thermostat regulates the operating temperature. The framework is made out of solid steel and comes with castors for easy transportation.
For ordinary area drum heater systems see our IDR, IBDR, and IDR-IBDR-CON product line.
SKU | P/N | Item | Std. size | Height ⁽¹⁾ | O.D. ⁽¹⁾ | Voltage | Rating ⁽²⁾ | Weight |
---|---|---|---|---|---|---|---|---|
ISS.A11.001 | 1235-08240101 | FIBDR-SRX/200L/230V/1150W/IEC | 200 liter | 78 mm | 546 mm | 230 Vac | 1150 W | 20 kg |
ISS.A11.002 | 1235-08240102 | FIBDR-SRQ/200L/230V/1170W/IEC | 200 liter | 78 mm | 546 mm | 230 Vac | 1170 W | 20 kg |
ISS.A11.003 | 1235-08240103 | FIBDR-SRB/200L/230V/530W/IEC | 200 liter | 78 mm | 546 mm | 230 Vac | 530 W | 20 kg |
Other dimensions and power specifications are available upon request.
⁽¹⁾ Tolerances according to DIN ISO 2768 c
⁽²⁾ Tolerances ±10% at 230 Vac and +10°C
Certifications/Approvals
CE, IEC
Specifications
General
- Manufacturer
- Chromalox
- Brand
- Isopad
- Unit of measurement
- Piece
Area specifications
- Area classification
- Hazardous area
- Zone
- Gas 1, 2 - Dust 21, 22
- Temperature class
- T2, T4, T6
- Ingress protection
- IP6X (IP65)
- Electrical protection class
- Class I
- Ambient temperature range
- –40 to +50°C
Certifications
- Approvals
- Component approval
- Certificate
- CE 0598 / Ex
- Marking
- Ex II 2 GD Ex e iam IIC T2 ... T6 Ex tD A21 IP6X T
- Norms
- EN, IEC Standard
Standard manufacturing sizes
- Length
- 1100 mm including castors
- Height
- 75 mm heating surface
- Outer diameter
- 546 mm
Heater construction
- Type
- Self-regulating heating cable
- Carrier
- Aluminium plate, anodised black
- Material of thermal insulation
- Mineral-fiber
- Thickness
- 50 mm
- Outer protection
- Sheet steel
- Paint
- Structured blue paint
Connection
- Connection lead length
- 2 m
- Lead cross section
- 2.5 mm²
- Maximum operating temperature
- 180°C
- Connection lead insulation material
- Silicone
Temperature control
- Thermostat (type)
- RAYSTAT-EX-03
- Sensor type
- Pt100 2-wire
- Controller range
- 0 to +499°C
- Ingress protection
- IP66
- Maximum ambient temperature
- –50 to +55°C
- Housing material
- Polyester glass-fibre reinforced
Technical data
- Frequency
- 50-60 Hz
- Maximum operating voltage
- 254 Vac (~1ph)
- Nominal operating voltage
- Depending on design
- Nominal power
- Depending on design
- Maximum operating temperature
- 65 to 120°C (depends on heating cable and T-class)