FIDR-SR

Features

  • Tmax 65 to 120°C
  • 1810, 3930 or 3990 W
  • IP6X (IP65)
Request a quote Give us a call or send an email phonelink_ring +31 (0)183 - 20 10 88 forward_to_inbox sales@tc-e.nl

Application

Isopad FIDR-SR drum heaters are used to provide medium flow and process temperature in hazardous environments. The special design including a self-regulating heating cable embedded in a solid metal housing ensures the maximum in safety at operating conditions. Using this design an additional temperature limiter is not necessary.
These heaters are designed for standard 200 liter drum sizes of and are fully component approved according to the latest standards of ATEX.

Drum Heater
The drum heater is made out of a twopieced metal housing to be opened and closed via hinges and fasteners standing on conductive castors. The solid design ensures stable operation even on unlevel surfaces. The metal housing carries the heating cable and evenly distributes the temperature to the drum. A mechanical thermostat regulates the operating temperature. Each drum heater includes a lid. To reduce heat loss at top it is recommended to use our insulated lid.

FIDR-SR product variants
SKU P/N Item Std. size Height ⁽¹⁾ I.D. ⁽¹⁾ O.D. ⁽¹⁾ Voltage Rating ⁽²⁾ Weight
ISS.A10.001 1235-99930131 FIDR-SRX/200L/230V/3930W 200 liter 990 mm 650 mm 770 mm 230 Vac 3930 W 60 kg
ISS.A10.002 1235-99930121 FIDR-SRQ/200L/230V/3990W 200 liter 990 mm 650 mm 770 mm 230 Vac 3990 W 60 kg
ISS.A10.003 - FIDR-SRB/200L/230V/1810W 200 liter 990 mm 650 mm 770 mm 230 Vac 1810 W 60 kg
ISS.A10.004 1235-08021000 FIDR/200L/LID/INSULATED 200 liter 85 mm 790 mm 798 mm - - 20 kg

Other dimensions and power specifications and components are available upon request such as design with other housing materials (e.g. stainless steel) or a JBU-100-L-E junction box with signal lamp for operating status (ON/OFF).

⁽¹⁾ Tolerances according to DIN ISO 2768 c
⁽²⁾ Tolerances ±10% at 230 Vac and +10°C

Resources

Datasheet
English
German

Certifications/Approvals

CE, IEC

Specifications

General

Manufacturer
Chromalox
Brand
Isopad
Unit of measurement
Piece

Area specifications

Area classification
Hazardous area
Zone
Gas 1, 2 - Dust 21, 22
Temperature class
T2, T4, T6
Ingress protection
IP6X (IP65)
Electrical protection class
Class I
Ambient temperature range
–40 to +50°C

Certifications

Approvals
Component approval
Certificate
CE 0598 / Ex
Marking
Ex II 2 GD Ex de IIC T2 ... T6 Ex tD A21 IP6X T240
Norms
EN, IEC Standard

Standard manufacturing sizes

Height
990 mm including castors
Inner diameter
650 mm
Outer diameter
770 mm

Heater construction

Type
Self-regulating heating cable
Carrier
Sheet steel
Material of thermal insulation
Glass-fiber
Thickness
50 mm
Outer protection
Sheet steel
Paint
Matt black heat resistant & structured blue paint
Fixation and closure type
Quick-snap fastener

Connection

Junction box (type)
STAHL Series 8118
Ingress protection
IP66
Maximum ambient temperature
–50 to +55°C
Maximum connecting cross section
4 mm²
Terminals
8
Glands
4 x M25
Housing material
Polyester glass-fiber reinforced
Connection lead length
2 m
Lead cross section
4 mm²
Maximum operating temperature
180°C
Connection lead insulation material
Silicone

Temperature control

Thermostat (type)
ETS-05-L2-E (P)
Sensor type
Pt100 3-wire
Controller range
0 to +199°C
Ingress protection
IP66
Maximum ambient temperature
–40 to +60°C
Housing material
Polyester glass-fibre reinforced

Technical data

Frequency
50-60 Hz
Maximum operating voltage
254 Vac (~1ph)
Nominal operating voltage
Depending on design
Nominal power
Depending on design
Maximum operating temperature
65 to 120°C (depends on heating cable and T-class)