IBDR

Features

  • Tmax 300°C
  • 900 or 4900 W
  • IP52 / IP65
Request a quote Give us a call or send an email phonelink_ring +31 (0)183 - 20 10 88 forward_to_inbox sales@tc-e.nl

Application

Isopad IBDR base drum heaters are used to provide medium flow and process temperature in ordinary environments. The special design including a high powered resistance heating cable embedded in a solid metal housing ensures the maximum on power output at operating conditions. These heating units can be used for higher temperatures and faster heat up times. These heaters are designed for standard drum sizes of 200 liter.

Base drum heater
The base drum heater is a perfect addition to the drum heater to prevent heat loss from below. A metal housing carries the heating cable and evenly distributes the temperature to the drum. An aluminum casted mechanical thermostat regulates the operating temperature by achieving a maximum on safety during operation.

Drum and base drum heater set
A combination of a drum and base drum heater was created to just use a single control mechanism. The base drum heater can be connected to the drum heater and is thereby controlled by one thermostat. This unit was designed for drum sizes of 200 liter.

For hazardous area drum heater systems see our FIDR-SR and FIBDR-SR product line.

IBDR product variants
SKU P/N Item Type Std. size Rating ⁽²⁾ Nom. voltage Weight
ISS.A09.005 514096-000 IBDR/200L/230V/900W Base heater 200 liter 900 W 230 Vac~1ph 20 kg
ISS.A09.003 931092-000 IDR-IBDR-CON/200L/230V/4900W Drum & base heater 200 liter 4900 W 230 Vac~1ph 60 kg
ISS.A09.004 1235-99900673 IDR-IBDR-CON/200L/400V/4900W Drum & base heater 200 liter 4900 W 400 Vac~3ph 60 kg

Other dimensions and power specifications and components are available upon request such as an alternative controller setting range 0°C to +43°C or +30°C to +110°C.

⁽¹⁾ Tolerances according to DIN ISO 2768 c
⁽²⁾ Tolerances ±10%

Resources

Datasheet
English
German

Certifications/Approvals

CE

Specifications

General

Manufacturer
Chromalox
Brand
Isopad
Unit of measurement
Piece

Area specifications

Area classification
Nonhazardous, ordinary area
Ingress protection
IP52
Electrical protection class
Class I
Ambient temperature range
–20 to +40°C

Standard manufacturing sizes

Height
75 mm heating surface
Outer diameter
570 mm

Heater construction

Type
Resistance heating cable
Material
Various alloys
Material of heater insulation
Glass-silk
Carrier
Woven glass-silk
Material of thermal insulation
Mineral-fiber
Thickness
50 mm
Outer protection type
Sheet steel
Paint
Matt black heat resistant & hammer trimite grey

Lead connection

Connection length
3.0 m
Cross section
2.5 mm²
Maximum operating temperature
80°C
Insulation material
Armored PVC

Temperature control

Thermostat type
TSW
Sensor type
Capillary tube
Controller range
50 to 300°C
Ingress protection
IP65
Maximum ambient temperature (IDR / IBDR)
–25 to +40°C / –20 to +80°C
Housing dimension (LxWxH)
170 x 150 x 100 mm
Housing material
Aluminium cast

Technical data

Frequency
50-60 Hz
Nominal operating voltage
230 Vac~1ph
Nominal power
900 W
Maximum operating temperature
300°C