Application
Isopad IBDR base drum heaters are used to provide medium flow and process temperature in ordinary environments. The special design including a high powered resistance heating cable embedded in a solid metal housing ensures the maximum on power output at operating conditions. These heating units can be used for higher temperatures and faster heat up times. These heaters are designed for standard drum sizes of 200 liter.
Base drum heater
The base drum heater is a perfect addition to the drum heater to prevent heat loss from below. A metal housing carries the heating cable and evenly distributes the temperature to the drum. An aluminum casted mechanical thermostat regulates the operating temperature by achieving a maximum on safety during operation.
Drum and base drum heater set
A combination of a drum and base drum heater was created to just use a single control mechanism. The base drum heater can be connected to the drum heater and is thereby controlled by one thermostat. This unit was designed for drum sizes of 200 liter.
For hazardous area drum heater systems see our FIDR-SR and FIBDR-SR product line.
SKU | P/N | Item | Type | Std. size | Rating ⁽²⁾ | Nom. voltage | Weight |
---|---|---|---|---|---|---|---|
ISS.A09.005 | 514096-000 | IBDR/200L/230V/900W | Base heater | 200 liter | 900 W | 230 Vac~1ph | 20 kg |
ISS.A09.003 | 931092-000 | IDR-IBDR-CON/200L/230V/4900W | Drum & base heater | 200 liter | 4900 W | 230 Vac~1ph | 60 kg |
ISS.A09.004 | 1235-99900673 | IDR-IBDR-CON/200L/400V/4900W | Drum & base heater | 200 liter | 4900 W | 400 Vac~3ph | 60 kg |
Other dimensions and power specifications and components are available upon request such as an alternative controller setting range 0°C to +43°C or +30°C to +110°C.
⁽¹⁾ Tolerances according to DIN ISO 2768 c
⁽²⁾ Tolerances ±10%
Certifications/Approvals
CE
Specifications
General
- Manufacturer
- Chromalox
- Brand
- Isopad
- Unit of measurement
- Piece
Area specifications
- Area classification
- Nonhazardous, ordinary area
- Ingress protection
- IP52
- Electrical protection class
- Class I
- Ambient temperature range
- –20 to +40°C
Standard manufacturing sizes
- Height
- 75 mm heating surface
- Outer diameter
- 570 mm
Heater construction
- Type
- Resistance heating cable
- Material
- Various alloys
- Material of heater insulation
- Glass-silk
- Carrier
- Woven glass-silk
- Material of thermal insulation
- Mineral-fiber
- Thickness
- 50 mm
- Outer protection type
- Sheet steel
- Paint
- Matt black heat resistant & hammer trimite grey
Lead connection
- Connection length
- 3.0 m
- Cross section
- 2.5 mm²
- Maximum operating temperature
- 80°C
- Insulation material
- Armored PVC
Temperature control
- Thermostat type
- TSW
- Sensor type
- Capillary tube
- Controller range
- 50 to 300°C
- Ingress protection
- IP65
- Maximum ambient temperature (IDR / IBDR)
- –25 to +40°C / –20 to +80°C
- Housing dimension (LxWxH)
- 170 x 150 x 100 mm
- Housing material
- Aluminium cast
Technical data
- Frequency
- 50-60 Hz
- Nominal operating voltage
- 230 Vac~1ph
- Nominal power
- 900 W
- Maximum operating temperature
- 300°C