IS-SP

Features

  • Tmax 450°C
  • Approx. 150 W/m
  • IP20
Request a quote Give us a call or send an email phonelink_ring +31 (0)183 - 20 10 88 forward_to_inbox sales@tc-e.nl

Application

Isopad IS-SP is a pre-terminated, very flexible heating cord consisting of a glass silk insulated, flexible fabric weave with interior heating conductors.

The temperature depends on the power and application. It is important to make sure that the heating cord does not exceed the maximum withstand temperature. Owing to its small dimensions, the heating cord is used for heating up and compensating for heat loss on short pipes, glass apparatus, or other structures, mainly for laboratory requirements. The heating cord is not moisture-protected and must only be used in dry areas.

IS-SP standard product variants
SKU P/N Item Length ⁽¹⁾ Voltage Rating ⁽²⁾
ISS.A02.001 175192-000 IS-SP/0.5M/230V/50W/KE1.5M 0.50 m 230 V 50 W
ISS.A02.002 209402-000 IS-SP/1.0M/230V/160W/KE1.5M 1.00 m 230 V 160 W
ISS.A02.003 490504-000 IS-SP/1.5M/230V/220W/KE1.5M 1.50 m 230 V 220 W
ISS.A02.004 030246-000 IS-SP/2.0M/230V/330W/KE1.5M 2.00 m 230 V 330 W
ISS.A02.005 217452-000 IS-SP/2.5M/230V/380W/KE1.5M 2.50 m 230 V 380 W
ISS.A02.006 920078-000 IS-SP/3.0M/230V/490W/KE1.5M 3.00 m 230 V 490 W
ISS.A02.007 610730-000 IS-SP/4.0M/230V/600W/KE1.5M 4.00 m 230 V 600 W
ISS.A02.008 927312-000 IS-SP/5.0M/230V/710W/KE1.5M 5.00 m 230 V 710 W
ISS.A02.009 514784-000 IS-SP/6.0M/230V/820W/KE1.5M 6.00 m 230 V 820 W

Other lengths and power specifications, etc. available on request.

⁽¹⁾ Tolerances
<2.0 m ± (1% + 50 mm)
>2.0 m ± (2% + 100 mm)
⁽²⁾ Tolerances ±10%

Resources

Datasheet
English
German

Installation manual
English/German

Certifications/Approvals

CE

Specifications

General

Manufacturer
Chromalox
Brand
Isopad
Unit of measurement
Piece

Area specifications

Area classification
Nonhazardous, ordinary area
Ingress protection
IP20
Electrical protection class
I or II (refer to the manual for more information)
Maximum withstand temperature (power off)
450°C
Storage temperature
–40 to +50°C
Minimum installation temperature
–40°C

Standard manufacturing sizes

Outer diameter (OD)
Maximum 6 mm

Heater construction

Type
Resistance heating cable
Material
Nickel-chrome-alloy
Material of insulation
Glass-silk for IS-SP
Material of outer sheath
Woven glass-silk

Lead connection

Connection length
Terminated at each end with a 1.5 m cold lead
Cross section
1.0 mm²
Maximum operating temperature
200°C
Insulation material
Silicone-glass-silk

Technical data

Frequency
50-60 Hz
Nominal operating voltage
230 Vac
Approximate power output per meter
150 W/m
Maximum operating temperature
450°C
Minimum bend radius
5 mm
Minimum spacing
5 mm