IS-SP-H

Features

  • Tmax 900°C
  • Approx. 180 W/m
  • IP20
Request a quote Give us a call or send an email phonelink_ring +31 (0)183 - 20 10 88 forward_to_inbox sales@tc-e.nl

Application

Isopad IS-SP-H is a pre-terminated, very flexible high temperature heating cord consisting of a quartz glass insulated, flexible fabric weave with interior heating conductors.

The temperature depends on the power and application. It is important to make sure that the heating cord does not exceed the maximum withstand temperature. Owing to its small dimensions, the heating cord is used for heating up and compensating for heat loss on short pipes, glass apparatus, or other structures, mainly for laboratory requirements. The heating cord is not moisture-protected and must only be used in dry areas.

IS-SP-H is a made-to-order heating cable, item numbers and further specifications are upon request.

IS-SP-H product variants
SKU P/N Item Length ⁽¹⁾ Cold lead ⁽¹⁾ Voltage Rating ⁽²⁾
ISS.A26.014 1235-91900462.3 IS-SP-H/5.0M/230V/710W/KE1.5M 5.00 m 1.50 m 230 V 710 W
ISS.A26.015 1235-99400469 IS-SP-H/6.0M/230V/820W/KE1.5M 6.00 m 1.50 m 230 V 820 W

Other lengths and power specifications, etc. available on request.

⁽¹⁾ Tolerances
<2.0 m ± (1% + 50 mm)
>2.0 m ± (2% + 100 mm)
⁽²⁾ Tolerances +5% / -10%

Resources

Datasheet
English
German

Installation manual
English/German

Certifications/Approvals

CE

Specifications

General

Manufacturer
Chromalox
Brand
Isopad
Unit of measurement
Piece

Area specifications

Area classification
Nonhazardous, ordinary area
Ingress protection
IP20
Electrical protection class
I or II (refer to the manual for more information)
Maximum withstand temperature (power off)
900°C
Storage temperature
–40 to +50°C
Minimum installation temperature
–40°C

Standard manufacturing sizes

Outer diameter (OD)
Maximum 6 mm

Heater construction

Type
Resistance heating cable
Material
Nickel-chrome-alloy
Material of insulation
Quartz-glass
Material of outer sheath
Woven quartz-glass

Lead connection

Connection length
Terminated at each end with a 1.5 m cold lead
Cross section
1.5 mm²
Maximum operating temperature
450°C
Insulation material
Woven quartz-glass

Technical data

Frequency
50-60 Hz
Nominal operating voltage
230 Vac
Approximate power output per meter
180 W/m
Maximum operating temperature
900°C
Minimum bend radius
5 mm
Minimum spacing
5 mm