Application
Isopad IS-SP-V is a pre-terminated, very flexible heating cord consisting of a glass silk insulated, flexible fabric weave with interior heating conductors. Contrary to the standard IS-SP, this heating cable is made with a central core to the spiral heating element.
The temperature depends on the power and application. It is important to make sure that the heating cord does not exceed the maximum withstand temperature. Owing to its small dimensions, the heating cord is used for heating up and compensating for heat loss on short pipes, glass apparatus, or other structures, mainly for laboratory requirements. The heating cord is not moisture-protected and must only be used in dry areas.
Other lengths and power specifications, etc. available on request.
⁽¹⁾ Tolerances
<2.0 m ± (1% + 50 mm)
>2.0 m ± (2% + 100 mm)
⁽²⁾ Tolerances ±10%
Certifications/Approvals
CE
Specifications
General
- Manufacturer
- Chromalox
- Brand
- Isopad
- Unit of measurement
- Piece
Area specifications
- Area classification
- Nonhazardous, ordinary area
- Ingress protection
- IP20
- Electrical protection class
- I or II (refer to the manual for more information)
- Maximum withstand temperature (power off)
- 450°C
- Storage temperature
- –40 to +50°C
- Minimum installation temperature
- –40°C
Standard manufacturing sizes
- Outer diameter (OD)
- Maximum 6 mm
Heater construction
- Type
- Resistance heating cable
- Material
- Nickel-chrome-alloy
- Material of insulation
- Glass-silk for IS-SP
- Material of outer sheath
- Woven glass-silk
Lead connection
- Connection length
- Terminated at each end with a 1.5 m cold lead
- Cross section
- 1.0 mm²
- Maximum operating temperature
- 200°C
- Insulation material
- Silicone-glass-silk
Technical data
- Frequency
- 50-60 Hz
- Nominal operating voltage
- 230 Vac
- Approximate power output per meter
- 150 W/m
- Maximum operating temperature
- 450°C
- Minimum bend radius
- 5 mm
- Minimum spacing
- 5 mm