Features

  • Tmax 450°C
  • Approx. 650 W/m
  • IP20
Request a quote Give us a call or send an email phonelink_ring +31 (0)183 - 20 10 88 forward_to_inbox sales@tc-e.nl

Application

The Isopad IT-G25 type is a factory terminated heating tape constructed from resistance foil or wire heating elements. The elements are stitched into a total of six layers (three per side) of glass tape, which acts as a carrier.

These tapes are suitable for indoor use or areas where there is no risk of moisture ingress.

IT-GW25 product variants
SKU P/N Item Length ⁽¹⁾ Voltage Rating ⁽²⁾
ISS.A02.026 017628-000 IT-G25/1.8M/230V/1084W/KE1.0M 1.80 m 230 V 1084 W
ISS.A02.027 891490-000 IT-G25/1.8M/230V/661W/KE1.0M 1.80 m 230 V 661 W
ISS.A02.028 396998-000 IT-G25/3.6M/230V/1630W/KE1.0M 3.60 m 230 V 1630 W
ISS.A02.029 131950-000 IT-G25/3.6M/230V/1084W/KE1.0M 3.60 m 230 V 1084 W
ISS.A02.030 940384-000 IT-G25/5.4M/230V/1451W/KE1.0M 5.40 m 230 V 1451 W
ISS.A02.031 604576-000 IT-G25/5.4M/230V/748W/KE1.0M 5.40 m 230 V 748 W
ISS.A02.032 207500-000 IT-G25/7.5M/230V/780W/KE1.0M 7.5 m 230 V 780 W
ISS.A02.033 667608-000 IT-G25/7.5M/230V/1901W/KE1.0M 7.5 m 230 V 1901 W
ISS.A02.034 743210-000 IT-G25/9.0M/230V/1735W/KE1.0M 9.0 m 230 V 1735 W
ISS.A02.035 068742-000 IT-G25/12.0M/230V/1436W/KE1.0M 12.0 m 230 V 1436 W

Other lengths and power specifications, etc. available on request.

⁽¹⁾ Tolerances
<2000 mm ± (1% + 50 mm)
>2000 mm ± (2% + 100 mm)
⁽²⁾ Tolerances ±10%

Resources

Datasheet
English
German

Installation manual
English/German

Certifications/Approvals

CE

Specifications

General

Manufacturer
Chromalox
Brand
Isopad
Unit of measurement
Piece

Area specifications

Area classification
Nonhazardous, ordinary area
Ingress protection
IP20
Electrical protection class
I or II (refer to the manual for more information)
Maximum withstand temperature (power off)
450°C
Storage temperature
–40 to +50°C
Minimum installation temperature
–40°C

Standard manufacturing sizes

Width
25 mm ±10%
Thickness
2 or 4 mm ±10% (depending on design)

Heater construction

Type
Resistance heating cable
Material
Various alloys
Material of insulation
Glass-silk
Material of outer sheath
Woven glass-silk

Lead connection

Connection length
1.0 m
Cross section
2 x 1.0 mm²
Maximum operating temperature
450°C
Insulation material
Glass-silk

Technical data

Frequency
50-60 Hz
Nominal operating voltage
230 Vac
Approximate power output per meter
650 W/m
Maximum operating temperature
450°C
Minimum bend radius
25 mm
Minimum spacing
5 mm