IT-S20

Features

  • Tmax 450°C
  • 220 W/m
  • IP20
Request a quote Give us a call or send an email phonelink_ring +31 (0)183 - 20 10 88 forward_to_inbox sales@tc-e.nl

Application

Isopad IT-S20 is a preterminated, flexible heating tape with a copper-tinned outer braiding serving as a protective earth braid. The temperature depends on the power and application. It is important make sure that the heating tape does not exceed the maximum withstand temperature.

This heating tape enables maximum power to be installed even in the case of small surfaces. The heating tape can be used for temperature modification of pipes and structures in the industrial and laboratory sectors.

IT-S20 product variants
SKU P/N Item Length ⁽¹⁾ Voltage Rating ⁽²⁾
ISS.A02.189 263604-000 IT-S20/0.5M/230V/110W/KE1.0M 0.50 m 230 V 110 W
ISS.A02.190 114346-000 IT-S20/1.0M/230V/220W/KE1.0M 1.00 m 230 V 220 W
ISS.A02.191 704368-000 IT-S20/1.5M/230V/330W/KE1.0M 1.50 m 230 V 330 W
ISS.A02.192 153620-000 IT-S20/2.0M/230V/440W/KE1.0M 2.00 m 230 V 440 W
ISS.A02.193 443830-000 IT-S20/3.0M/230V/650W/KE1.0M 3.00 m 230 V 650 W
ISS.A02.194 054874-000 IT-S20/5.0M/230V/1090W/KE1.0M 5.00 m 230 V 1090 W
ISS.A02.195 522884-000 IT-S20/7.0M/230V/1530W/KE1.0M 7.00 m 230 V 1530 W
ISS.A02.196 261076-000 IT-S20/10.0M/230V/2180W/KE1.0M 10.00 m 230 V 2180 W

Other lengths and power specifications, etc. available upon request.

⁽¹⁾ Tolerances
<2000 mm ± (1% + 50 mm)
>2000 mm ± (2% + 100 mm)
⁽²⁾ Tolerances ±10%

Resources

Datasheet
English
German

Installation manual
English/German

Certifications/Approvals

CE

Specifications

General

Manufacturer
Chromalox
Brand
Isopad
Unit of measurement
Piece

Area specifications

Area classification
Nonhazardous, ordinary area
Ingress protection
IP20
Electrical protection class
Class I
Maximum withstand temperature (power off)
450°C
Storage temperature
–40 to +50°C
Minimum installation temperature
–40°C

Standard manufacturing sizes

Width
12 mm ±10%
Thickness
7 mm ±10%

Heater construction

Type
Resistance heating cable
Material
Nickel-chrome-alloy
Material of insulation
Glass-silk
Material of outer sheath
Copper-nickel braid

Lead connection

Connection length
1.0 m
Cross section
2 x 1.5 mm²
Maximum operating temperature
200°C
Insulation material
Silicone-glass-silk

Technical data

Frequency
50-60 Hz
Nominal operating voltage
230 Vac
Approximate power output per meter
220 W/m
Maximum operating temperature
450°C
Minimum bend radius
15 mm
Minimum spacing
5 mm