Application
Isopad IT-GW27 is a factory-terminated heating tape manufactured from a PTFE electrically insulated, resistance wire extruded in silicone rubber.
The construction of this heating tape allows it to be used in wet environments. The outer jacket is smooth and may be washed down for cleaning, which also makes it suitable for use in dirty areas.
The IT-GW27 must be used with an appropriate temperature controller, see the controllers and sensors page for Isopad's selection of temperature controllers and sensors.
SKU | P/N | Item | Length ⁽¹⁾ | Voltage | Rating ⁽²⁾ |
---|---|---|---|---|---|
ISS.A02.017 | 1235-88303562 | IT-GW27/3.6M/230V/551W/KE1.0M | 3.60 m | 230 V | 551 W |
ISS.A02.018 | 1235-88303563 | IT-GW27/4.0M/230V/270W/KE1.0M | 4.00 m | 230 V | 270 W |
ISS.A02.019 | 1235-88303564 | IT-GW27/5.4M/230V/733W/KE1.0M | 5.40 m | 230 V | 733 W |
ISS.A02.020 | 1235-88303565 | IT-GW27/6.0M/230V/330W/KE1.0M | 6.00 m | 230 V | 330 W |
ISS.A02.021 | 1235-88303566 | IT-GW27/8.0M/230V/367W/KE1.0M | 8.00 m | 230 V | 367 W |
ISS.A02.022 | 1235-88303567 | IT-GW27/9.0M/230V/864W/KE1.0M | 9.00 m | 230 V | 864 W |
ISS.A02.023 | 1235-88303568 | IT-GW27/10.0M/230V/588W/KE1.0M | 10.00 m | 230 V | 588 W |
ISS.A02.024 | 1235-88303569 | IT-GW27/12.0M/230V/1320W/KE1.0M | 12.00 m | 230 V | 1320 W |
ISS.A02.025 | 1235-88303570 | IT-GW27/15.0M/230V/1567W/KE1.0M | 15.00 m | 230 V | 1567 W |
Other lengths and power specifications, etc. available on request.
⁽¹⁾ Tolerances
<2000 mm ± (1% + 50 mm)
>2000 mm ± (2% + 100 mm)
⁽²⁾ Tolerances ±10%
Certifications/Approvals
CE
Specifications
General
- Manufacturer
- Chromalox
- Brand
- Isopad
- Unit of measurement
- Piece
Area specifications
- Area classification
- Nonhazardous, ordinary area
- Ingress protection
- IP67
- Electrical protection class
- Class II
- Maximum withstand temperature (power off)
- 200°C
- Storage temperature
- +5 to +30°C
- Minimum installation temperature
- -60°C
Standard manufacturing sizes
- Width
- 27 mm ±10%
- Thickness
- 5 mm ±10%
Heater construction
- Type
- Resistance heating cable
- Material
- Various alloys
- Material of insulation
- PTFE
- Material of outer sheath
- Silicone
Lead connection
- Connection length
- 1.0 m
- Cross section
- 2 x 1.5 mm²
- Maximum operating temperature
- 180°C
- Insulation material
- Silicone
Technical data
- Frequency
- 50-60 Hz
- Nominal operating voltage
- 230 Vac
- Approximate power output per meter
- Up to 150 W/m (depending on application)
- Maximum operating temperature
- 200°C
- Minimum bend radius
- 25 mm
- Minimum spacing
- 5 mm